Impact Testing Machine (Mechanical)
Mechatronic make Impact Testing Machine Model M – IT30 is designed for conducting Izod &Charpy Test. The test methods confirm to BS : 131 : PART 4 – 1972 (Amended 15 Aug. 1993) & BSEN : 10045-2 : 1993 The Pendulum is mounted on antifriction bearings.
Model: M IT30
Brand: Mechatronic
Applications: Hardness Testing
Industries: Aerospace, Automotive, Electronics, Inks and Coatings, Metal Packaging
Materials: Aluminum, Steel
Mechatronic make Impact Testing Machine Model M – IT30 is designed for conducting Izod &Charpy Test. The test methods confirm to BS : 131 : PART 4 – 1972 (Amended 15 Aug. 1993) & BSEN : 10045-2 : 1993 The Pendulum is mounted on antifriction bearings. It has two starting positions, the upper one for Charpy and the lower one for Izod testing. On release, the Pendulum swing down to break the specimen and the energy absorbed in doing so is measured as the difference between the height of drop before rupture & height of raise after rupture of the test specimen and is read from the maximum pointer on the dial scale.
SPECIFICATION | M – IT 30 | M – IT 30 E |
---|---|---|
Maximum Capacity | 300 J / 168 J | 300 J / 170 J |
Minimum Scale Graduation | 2 J | 0.5 J |
Overall Size (Approx.) | 1.65 m (H) | 1.65 m x 0.45 mx |
1.1 m x 045 mx | 1.65 m (H) | |
Net Weight (Approx.) | 375 Kg. | 375 Kg. |
- Caliper gauge for checking V notch for Izod & Charpy as per BS : 131 : PART 1, 2, 3
- Depth notch gauge including V & U notch, angle & radius.
- Self centering tong.
- V – notch milling cutter.
- U – notch milling cutter.